                 BOD 
                  Sensor System | 
               
               
                   
                   | 
               
               
                
                     
                      - 
                        ¹Ì»ý¹°ÀÌ È£ÈíÇÏ¸ç ¹ß»ýÇÑ CO2°¡½ºÀÇ ¾Ð·ÂÀ» ÀÌ¿ëÇÑ Á¤¹ÐÇÑ microprocessor ¾Ð·Â ¼¾¼¿¡ 
                        ÀÇÇÏ¿© BOD°ªÀ» Digital·Î Ç¥½Ã. 
                        - BOD°ªÀº 24½Ã°£ °£°ÝÀ¸·Î 7Àϰ£ ÀÚµ¿ ÀúÀåµÇ¹Ç·Î ¸ÅÀÏ È®ÀÎÇÒ ¹ø°Å·Î¿òÀ» ÇØ¼Ò. 
                        - º°µµÀÇ Á¶Á¤Å°°¡ ¾øÀÌ °£´ÜÇÏ°Ô BOD°ªÀ» ¼ø°£Ä¡¿Í ÀúÀåµÈ °ªÀ» È®ÀÎÇÒ ¼ö ÀÖ´Ù.  
                        - ¼ø°£ BOD, 5ÀÏ BOD, Total BOD°ª µîÀÌ ÃøÁ¤ °¡´É. 
                        - BOD Sensor System ±¸¼ºÀº BOD Sensor, Àü¿ë ±³¹Ý±â, BOD Incubator·Î 
                        ±¸¼ºÇØ¾ß ÇÔ.
  | 
                     
                    | 
               
               
                |   | 
               
               
                  | 
               
               
                
                     
                      - 
                        Digital Direct reading of valves in mg/l 
                        - BOD valves (ppm) directly on display at any time also 
                        after the standard 5days period 
                        - After BOD5 it is possible to determine total BOD 
                        - Method : Measurement by electronic pressure probe 
                        - Memorized Data : BOD5 values at 24 hours intervals 
                        - Diplay : Digits 3 LED, 7mm high 
                        - Scales : 90, 250, 600, 999ppm BOD. Higher values, after 
                        dilution 
                        - Power Supply : 2 Lithium batteriesn (250 mAh) type CR2430 
                        - Battery Life : 2 years 
                        - Safty class : 3 IEC 1010 
                        - Protection Degree : IP 44 IEC 529 
                        - Measuring No. : 6 places (BOD Sensor System 6) 
                        : 10 places (BOD Sensor System 10)
  | 
                     
                    | 
               
              
                |   | 
               
               
                
                     
                       | 
                     
                     
                      Model 
                          [ BOD Sensor System 6, 10 ]  | 
                     
                    | 
               
               
                |   | 
               
              
             
           | 
            
			 
		 |